CNAS-accredited testing for HV/LV power system electrical equipment

The high voltage electrical testing centre of Yonggu Group — an accredited laboratory covering power cables and wires, power fittings, cable accessories, insulators and surge arresters, and HV/LV electrical products: pole-mounted vacuum circuit breakers, disconnectors, load-break switches, fuses and pole-mounted substation assemblies. We test to IEC, GB and EN standards and issue English-language reports that hold up to utility specifications, tender requirements and customs review.

CNAS L7721 — valid to 26 May 2030 Reports issued in English
Accreditation & recognition
CNAS L7721 ISO/IEC 17025:2017 ILAC-MRA mutual recognition Accredited since 2015 Yonggu Group · since 1985
What we do

Five test disciplines, one accredited quality system

Six dedicated laboratories and one sample flow — from reception and identification through testing to report issue, under ISO/IEC 17025:2017.

Electrical testing

Power-frequency withstand, lightning impulse, partial discharge, DC resistance, temperature rise, thermal cycling and power characteristics on fittings, cables and switchgear.

Electrical test scope

Mechanical testing

Failing load, slip load, tensile and fatigue testing to the load defined in the standard — including a 600 kN servo-hydraulic horizontal tensile machine for long fittings.

Mechanical test scope

Material analysis

Chemical composition by OES, handheld XRF and SEM with EDS; metallography under a ZEISS microscope; coating mass and microstructure of aluminium and copper products.

Material test scope

Ageing & environment

Heat ageing in controlled ovens and xenon-arc ageing for insulation, sheath compounds and polymer components — the tests that decide service life in tropical and desert climates.

Ageing test scope

NDT & failure analysis

X-ray digital radiography, dye penetrant, ultrasonic and magnetic inspection — plus failure analysis after a claim, with a technical report suitable for negotiation or insurance.

NDT & analysis

Not sure which test applies?

Send us the product drawing and the standard quoted in your tender. An engineer replies with a test plan, sample requirement, price and lead time within one working day.

Ask the laboratory
Why the reports are accepted

Evidence that survives scrutiny

For an export project, a test report is only useful if the buyer, the utility and the customs authority accept it. The laboratory is accredited by CNAS and its scope sits inside the ILAC Mutual Recognition Arrangement, so results travel.

  • Testing accredited to ISO/IEC 17025:2017 under CNAS L7721
  • Mutual recognition through CNAS as a signatory of ILAC-MRA
  • English reports with clause-by-clause results and stated measurement uncertainty
  • Instrument traceability held for every test in the report
  • Online verification for every report number issued
  • One named engineer per project, from enquiry to after-sales

Group backing

The laboratory belongs to Yonggu Group, a manufacturer of transmission and distribution materials and HV/LV electrical products founded in 1985 — which is why the test benches, the metallurgy and the failure analysis are in house rather than outsourced.

1985

Group founded in Yueqing, Zhejiang

4

International standards co-authored

100+

Patents held by the group

2015

Year the laboratory was first accredited

The laboratory sits inside the manufacturer's technology centre, and is organised so that testing answers to the quality system, not to the sales department. What this means for the standing of a report is set out plainly on the accreditation page.

Lead times

Typical turnaround

Excluding sample transport. Express slots are available for tender deadlines — ask before you ship.

Test packageWorking daysExpress
DC resistance & dimensional check (fittings, conductors)53
LV cable routine tests (conductor resistance, dimensions, voltage test)75
MV cable type test (partial discharge, 4 h voltage test, insulation thickness)129
Mechanical failing load / slip load (fittings)75
Temperature rise & thermal cycling (connectors, busbar)107
Lightning impulse type test (switchgear, insulators)2015
Material composition & metallography75
Heat ageing / xenon-arc ageingPer standard cycle

Turnaround starts when the sample and the confirmed test plan are both received. Ageing programmes run to the cycle defined in the applicable standard.

Products

What we test

The accredited scope covers roughly 200 test items across about 80 national standards, spanning power cables and line materials as well as high- and low-voltage electrical products. The families below account for most export projects.

Product familyMain standardsRepresentative tests
Power cables & wires
LV and MV XLPE / PVC power cable, ABC, bare conductors
IEC 60502, IEC 60227, IEC 61089, GB/T 12706, GB/T 5023 Conductor DC resistance, insulation thickness, partial discharge, AC withstand, ageing, flame propagation
Power fittings
Tension & suspension clamps, connectors, line hardware
IEC 61284, GB/T 2314, GB/T 14315, GB/T 9327, DL/T 2340 Failing load, slip load, galvanising mass, metallography, DC resistance
Cable accessories
LV and MV heat-shrink and cold-shrink terminations, joints, sealing ends, waterproof boxes (1–35 kV)
IEC 60502, GB/T 12706, GB/T 9327 Power-frequency withstand, partial discharge, thermal cycling, ageing
Insulators & arresters
Composite and porcelain insulators, surge arresters
IEC 61109, IEC 60099-4, GB/T 19519, GB/T 11032 Power-frequency withstand, lightning impulse, mechanical failing load, ageing
HV switchgear & distribution apparatus
Pole-mounted vacuum circuit breakers (10 & 35 kV, incl. primary-secondary integrated), disconnectors and earthing switches, load-break switches, HV fuses, enclosed switchgear, pole-mounted substation assemblies
IEC 62271-1, IEC 62271-100, IEC 62271-102, IEC 62271-103, IEC 62271-200, IEC 60282-1, GB/T 11022, GB/T 1984, GB/T 1985, GB/T 3906, GB/T 15166 Withstand voltage, lightning impulse, temperature rise, mechanical operation, short-time current, over-current
LV electrical products
LV switchgear and controlgear assemblies, moulded-case and miniature circuit breakers, distribution boards and enclosures
IEC 61439-1, IEC 60947-1, IEC 60947-2, IEC 60529, GB/T 7251.1, GB/T 14048.1, GB/T 14048.2 Withstand voltage, temperature rise, mechanical operation, over-current, enclosure and IP checks
Copper & aluminium products
Tube busbar, conductors, sheet and profiles
IEC 61089, GB/T 3190, GB/T 5231, GB/T 5585 Chemical composition, tensile strength, elongation, DC resistivity, dimensions

Standards by country or region

Cables and wires are ordered against national standards that are not interchangeable. The table below maps the standard each market normally quotes, so the test plan can be written against the right one from the start.

Country / regionLV power cable (0.6/1 kV)MV power cableWires and building wire (450/750 V and below)
International (IEC) IEC 60502-1 IEC 60502-2 IEC 60227 (PVC), IEC 60245 (rubber)
China (GB) GB/T 12706.1; conductors GB/T 3956 GB/T 12706.2, GB/T 12706.3 GB/T 5023.1–.7, JB/T 8734, JB/T 10491 (XLPE)
European Union (CENELEC / HAR) HD 603 S1 HD 620 S1 EN 50525-1/-2/-3 (replacing HD 21 and HD 22)
United Kingdom BS 5467 (XLPE/SWA), BS 6346 (PVC/SWA), BS 6724 BS 6622 (PVC), BS 7835 (LSZH), BS 7870-4.10 BS EN 50525, BS 6004, BS 6500, BS 7211; fire BS 6387, BS 7629-1
Germany DIN VDE 0276-603 (= HD 603), types NAYY / NA2XY DIN VDE 0276-620 (XLPE), 0276-621 (PVC) DIN VDE 0281 (PVC), DIN VDE 0282 (rubber), DIN VDE 0250 (NYM-J / NYY-J)
France NF C 32-321 (now XP C 32-321) = U-1000 R2V NF C 33-226 (XLPE, 6/10 to 18/30 kV) NF C 32-201 (H07V-U / -K)
Italy CEI UNEL 35375 (FG7R / FG7OR / FG7OH1R / FG7OH2R), 35756 / 35757 (N1VV-K) CEI 20-13 (elastomeric G7, rubber-insulated, 1–30 kV), CEI 20-89 CEI UNEL 35752 (N07V-K), 35368 (N07G9-K)
Spain UNE 21123-2 (RV-K), UNE 211435 (RZ1-K, halogen-free) UNE 21123, UNE 211435 (MV types) UNE 21031 (H07V-K)
Russia GOST 31996-2012 (VVG / AVVG); conductors GOST 22483 GOST R IEC 60502-2 GOST 6323-79 (PV), GOST 7399-97 (PVS)
Kazakhstan GOST 31996-2012, ST RK IEC 60502-1 GOST R IEC 60502-2 GOST 6323-79, GOST 7399-97
Kyrgyzstan GOST 31996-2012 GOST R IEC 60502-2 GOST 6323-79, GOST 7399-97
Uzbekistan O’zDSt-IEC-60502-1 O’zDSt 2703-2021 (referring to GOST R IEC 60502-2) GOST 6323-79, GOST 7399-97
Tajikistan GOST 31996-2012 GOST R IEC 60502-2 GOST 6323-79, GOST 7399-97
Turkmenistan GOST 31996-2012 GOST R IEC 60502-2 GOST 6323-79, GOST 7399-97
North America (US and Canada) UL 44, UL 83, ICEA S-95-658; Canada CSA C22.2 No. 75 / No. 38 ICEA S-93-639, AEIC CS8, UL 1072; Canada CSA C22.2 No. 131 (TECK90), No. 239 UL 83 (THHN / THWN-2), UL 62; Canada CSA C22.2 No. 75 / No. 38 / No. 49
Japan and Korea JIS C 3605 (600 V IV / HIV), KS C IEC 60502-1 JIS C 3606 (CV), KS C IEC 60502-2 JIS C 3307, JIS C 3662, KS C IEC 60227
Australia and New Zealand AS/NZS 5000.1 AS/NZS 1429.1 AS/NZS 5000.2, AS/NZS 3191 (flexible cords), AS/NZS 1125 (conductors)
India IS 1554-1 (PVC), IS 7098-1 (XLPE) IS 7098-2 IS 694, IS 8130 (conductors)
Brazil ABNT NBR 7288 ABNT NBR 6251 ABNT NBR NM 247-3 / -5, NBR 13248 (XLPE 0.6/1 kV)
South Africa SANS 1507 SANS 1339 SANS 1507 series
Middle East and Türkiye IEC 60502-1 / BS 5467 as called up by SASO, ESMA and DEWA; TS IEC 60502-1 (NYY) IEC 60502-2 / BS 6622; TS IEC 60502-2 BS EN 50525, TS EN 50525, TS IEC 60227 (NYA / NYAF)

Voltage classes used above

ClassRangeMain standards
Low voltage Up to 1 kV — 0.6/1 kV in most systems; a 600 V class applies in North America and Japan IEC 60502-1
Medium voltage 3.6/6, 6/10, 8.7/15, 12/20, 18/30 and 26/35 kV IEC 60502-2
High voltage Above 36 kV IEC 60840, IEC 62067

The medium-voltage boundary moves with the system: roughly 6–30 kV under IEC and GB, 6.6–33 kV under BS, 5–46 kV under IEEE. Tell us which system the tender uses and we will quote against that definition.

North American building wire (600 V class)

The 600 V class is a parallel system to IEC 0.6/1 kV, not an equivalent one: it applies the same limit to line-to-earth and line-to-line, and it has no 3.5 kV / 5 min routine withstand test, relying instead on spark testing and UL follow-up service. Letter code: T thermoplastic · H 75 °C · HH 90 °C · W wet location · N nylon jacket · “2” wet-rated 90 °C.

DesignationInsulationDryWetStandardNote
TWPVC60 °C60 °CUL 83Older type, being phased out
THW / THW-2PVC75 / 90 °C75 / 90 °CUL 83
THHNPVC + nylon90 °C75 °CUL 83The most frequent selection error — the wet rating drops to 75 °C
THWN / THWN-2PVC + nylon75 / 90 °C75 / 90 °CUL 83Usually dual-marked “THHN/THWN-2”
XHHW / XHHW-2XLPE90 °C75 / 90 °CUL 44Thinner insulation, so more conductors fit the same raceway
RHW / RHW-2XLPE75 / 90 °C75 / 90 °CUL 44Available for 600 V or 2 kV
RHHThermoset90 °CNot ratedUL 44Dry locations only
SA / Z / FEPSilicone rubber / special200 / 150 °CDry onlyUL 44, UL 83Special applications

Canadian designations (CEC / CSA)

DesignationStandardNote
T90CSA C22.2 No. 75 (equivalent to UL 83)PVC + nylon; 90 °C dry, 75 °C wet, 60 °C oil; installable down to −10 °C
TW75CSA C22.2 No. 75Single-core PVC, 75 °C
RW90 / RWU90CSA C22.2 No. 38 (equivalent to UL 44)XLPE; 90 °C dry and wet; −40 °C; RWU90 is 1 kV and may be direct-buried
NMD90 / NMWU90CSA C22.2 No. 48Non-metallic sheathed; 300 V only, not the 600 V of US NM-B
AC90 / ACG90 / ACWU90CSA C22.2 No. 51Armoured
TECK90CSA C22.2 No. 131Industrial armoured, 1000 V / 90 °C, FT4, −40 °C
USEI90 / USEB90CSA C22.2 No. 52Service entrance cable
TC / TC-ER, CICCSA C22.2 No. 239Tray cable and instrumentation cable

Related US standards: UL 854 (SE / USE service entrance cable) · UL 719 (NM-B, 600 V) · UL 1063 (MTW machine-tool wire) · UL 62 (flexible cord) · ICEA S-95-658 / NEMA WC 70 for 0.6/1 kV power cable construction.

Points that change the answer

  • Ampacity basis. NEC Table 310.16 assumes a 30 °C ambient, no more than three current-carrying conductors, in raceway or cable tray, and gives separate 60 / 75 / 90 °C columns; 110.14(C) (the column is chosen by terminal temperature) and 240.4(D) (15 A for 14 AWG, 20 A for 12 AWG, 30 A for 10 AWG) both limit what the table appears to allow. IEC 60364-5-52 and GB 16895 instead use 30 °C air and 20 °C soil with installation-method tables, then apply correction factors for ambient temperature, grouping and soil thermal resistivity.
  • Cross-section systems. North America uses AWG / kcmil, IEC uses mm². Any conversion has to state whether it is an equivalent or an actual cross-section — 12 AWG and 4 mm² are not the same conductor.
  • Flame retardancy. US practice (VW-1, FT1, FT4, IEEE 1202, UL 1685) and IEC / European practice (IEC 60332-1, IEC 60332-3, EN 50575 CPR classes Eca to B2ca) are separate systems and are not mutually recognised, so each has to be demonstrated on its own terms.
  • Central Asia. Grid projects there usually also call up GOST 31565-2012 (fire safety requirements for cables) and GOST 22483 (conductors, equivalent to IEC 60228).

Installation codes quoted alongside

BS 7671 (18th edition, UK) · REBT and ITC-BT (Spain) · CEI 64-8 (Italy) · NF C 15-100 (France) · DIN VDE 0100 (Germany) · GB 50054 (China) · PUE (Russia and Central Asia) · NEC / NFPA 70 and CSA C22.1 (North America) · AS/NZS 3000 (Australia and New Zealand) · NBR 5410 (Brazil) · SANS 10142-1 (South Africa).

The standard numbers on this page identify the specification a product is ordered against; they are not by themselves an accredited test item. The accredited schedule lists Chinese national (GB) standards, and equivalent IEC, EN and other national methods are carried out under the same quality system and identified separately in the report. Send us the standard the buyer quotes and we will confirm, item by item, what is inside the accredited scope and what is not.

How it works

From enquiry to report

1

Send the requirement

Product drawing or datasheet, the standard quoted by the buyer, quantity and deadline. Use the online enquiry form or email.

2

Confirm the test plan

We reply with the test items, sample quantity, price and lead time, and state clearly whether each item is inside the accredited scope.

3

Ship the sample

Mark the parcel as a test sample with no commercial value and quote the test plan number. Reception photographs and bar-codes the sample on arrival.

4

Testing and technical review

The sample is routed to the relevant laboratory. Every result is reviewed against the clause of the standard before the report is released.

5

Report and verification record

A signed PDF is issued first, followed by the original by courier. The report number resolves in the online verification tool.

Have a tender deadline?

Send us the standard and the sample list. We will tell you within one working day what can be done, how long it takes and what it costs.